Description
Has an analogue DCVG movement for locating and reading off electrical measurement data
2GB internal memory.
- Digital Screen for viewing data
- Meter Sensitivity Range: 10mV to 10V
- 1 x Bias Probe Handle and 1 x Single Connector Handle
- Bias Probe handle charged off the Maximus DCVG meter Battery
- Comes with GPS Satellite Aerial
- Backpack with aerial stand
- Analysis software to calculate %IR Severity automatically and to create graphs and tables.
- Integrated GPS for accurate distance measurement.
- Locate epicentre of coating defects using analogue meter movement with the CP system pulsed ON and OFF by interrupter.
- Obtain Digital copy of Data.
- Manually determine Signal Strength at test posts: calculated P/RE
- Manually determine OL/RE
- Record a digital copy of data, both by summing using the reference probes and by using a 15 metre cable.
- Manually determine Corrosion Status at Coating Defect Epicentre to Remote Earth using the analogue DCVG meter
- Record a digital copy of corrosion status data using 15 metre cable using digital display and logger.
- Limited to a satellite synchronised interrupter (50 or 125amp)
- Maximus DCVG can manually and automatically record the corrosion status using a 15 metre cable.
- For corrosion status within Maximus DCVG anodic is a + and cathodic is a -.
- Full set comes with all items requires to do a survey
- ncluding carry cases